Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T03VL00611
Case Details
Entered Date:
06/24/2003
Applicant:
JE & RJ LLC
Description:
COMPLAINT:EMERGENCY CALLOUT - MOBILE HOME FIRE
Outstanding Inspections
Case Number: T03VL00611
Case Status: COMPLIAN
Case Description: COM: FIRE
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/23/2003 | INITIAL CODE VIOLATION | RMAJUTA | Violation | DAMAGED REPORT: LOCATION: WATER HEATER ROOM AND SOUT BED ROOM AND UNDER MH BOTH AREAS; BUILDING: FLOORING IN BOTH AREAS, FRAMING UNDER MH COMPLETELY DAMAGED; ELECTRICAL: 3 WIRES UNDER BEDROOM FLOORING COMPLETELY DAMAGED, OTHER CIRCUITRY PASSING DAMAGED; PLUMBING: GAS LINE TO WATER HEATER BURNED, ATER LINES OUT OF WH TO BE CHECKED. MECHANICAL: NONE SUMMARY: MOBILE HOME IS OLD AND HAS QUESTIONABLE FLOORING MAINLY PARTICLE BOARD. PERMITS FOR REPAIR ON ELECTRICAL, PLUMBING, BUILDING AND MECHANICAL TO BE TAKEN OUT FOR REPAIR UNLESS UNIT MOVED OUT. NO GAS OR ELECTRICAL TILL INSPECTED. |
06/23/2003 | INITIAL CODE VIOLATION | RMAJUTA | Violation | EMERGENCY CALLOUT - MOBILE HOME FIRE N&O INDEMNIFICATION SIGNED BY EDWARD MENDEZ EMERGENCY CALLOUT DUE TO FIRE IN MOBILE HOME, ELECTRICAL AND GAS DISCONNECTED, OWNER GIVEN N&O, OWNER TO BOARD UP 2 BROKEN WINDOWS,F IRE APPEARS TO HAVE STARTED ON FLOORING WATER HEATER ROOM, WATER HEATER SANK WITH WEIGHT AND WAS RESTING ON PARTICLE FLOORING (WOOD), THEN TRAVELING UNDER MH TO SOUTH MOST BEDROOM, FLOORING DESTROYED COMPLETELY BY FIRE. ELECTRICAL WIRING DAMAGED UNDER FLOORING, FRAMING COMPLETELY DAMAGED. OCCUPANTS VACATED, DOORS LOCKABLE, 2 WINDOWS TO BOARD UP. PERMITS REQUIRED FOR MH IF TO REPAIR - NO GAS NO ELECT TILL REPAIRED AND INSPECTED. OWNER MAY REMOVE FROM SITE. F/U 07/23/03 |
Completed Inspections
Case Status: COMPLIAN
Case Number: T03VL00611
Case Description: COM: FIRE
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/28/2003 | FOLLOW UP CODE VIOLATION | RMAJUTA | Approved | NO ACTIVITY STILL VACANT & SECURED. OK TO CLOSE PER INSPECTOR. |