Case: T03VL00485
Case Details
Entered Date:
05/09/2003
Applicant:
FOUNTAIN OF LIFE EVANGELICAL LUT
Description:
EMERGENCY CALL: FIRE
Outstanding Inspections
Case Number: T03VL00485
Case Status: CLOSED
Case Description: COM: FIRE
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/07/2003 | INITIAL CODE VIOLATION | RMAJUTA | Correction Required | VERIFIED UTILITIES DISCONNECTED BOTH GAS AND ELECTRIC INSPECTED DAMAGE, FIRE COMPLETELY DESTROYED BACK SECTION WHICH INCLUDED SEPERATE APARTMENT WITH KITH & BATH, OWN ELECT PANEL, APPEAL TO HAVE BEEN STUDIO APT. BACK 3 BEDROOMS HEAILY SMOKE DAMAGED, BURNED FIXTURES AND ALL FACIAL, 3 LARGE OPENINGS IN ROOF BY TFD, SEVERAL CEILING AREAS IN BACK 4 BEDROOMS TORN OFF TO FIGHT FIRE FRONT HALL BEDROOM, LIV RM KIT, ENTRY HEAVILY SMOKE DAMAGED. POWER & GAS TO REMAIN OFF UNTIL ALL PERMITS FOR ALL TRADES SECURED AND INSPECTIONS APPROVED. OWNER THRU OCCUPANT TO SECURE REAR WINDOWS AND DOORS TO PREVENT ENTRY. CAUSE OF DAMAGED: FIRE AT REAR OF STRUCTURE. LOCATION OF DAMAGE: THIRD REAR SECTION OF HOUSE INCLUDING STUDIO APT, REAR THREE BEDROOMS COMPLETE FIRE DAMAGE BUILDING: FRAMING ON STUD/APT COMPLETE FIRE DAMAGED ALL STRUCTURAL & ROOF, BACK THREE BEDROOMS OF HOUSE AND HALL (CEILING AND WALLS AND ROOF SECTIONS) BADLY DAMAGED BY FIRE AND SMOKE. ELECTRICAL: ALL STUDIO WIRING INCLUDING OUTSIDE PNL 3 REAR BEDROOM WIRING DAMAGED SOME HALL WIRING DAMAGED. PLUMBING: ALL IN STUDIO, PARTIAL LINES IN HALL AT HOUSE. MECHANICAL: DUCT WK THUR OUT HOUSE DAMGED HEATING UNIT IN STUDIO COMPLETE DAMAGE SUMMARY OF REMARKS REAR 1/2 OF HOUSE TO BE PERMITED FOR ALL TRADES STUDIO TO BE COMPLETELY PERMITED FOR ALL TRADES OCCUPANT TO BOARD UP ALL ENTRIES AND DAMAGED WINDOWS TO SECURE AGAINST ENTRY TONIGHT. FOLLOW UP 6/9/03 |
Completed Inspections
Case Status: CLOSED
Case Number: T03VL00485
Case Description: COM: FIRE
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/09/2003 | FOLLOW UP CODE VIOLATION | LHANLY | Approved | FRONT AND REAR WINDOWS OPEN. APPEARS TEENAGERS MAY BE ACCESSING, LARGE PILES OF FIRE DEBRIS AND MATTRESSES IN REAR AND SIDE YARDS. INSPECTOR RECOMMENDS THIS CASE BE TURNED OVER TO DNR AS 4 MONTHS HAVE PASSED WITH NO CLEAN UP. |