Case: T03DV01222
Case Details
Entered Date:
12/17/2003
Applicant:
BURGOS MARIO A & MARIA L CP/RS
Description:
COMPLAINT:BASEBOARD HEATER NOT HEATING PROPERLY AND REPAIRS NOT BEEN DONE.
Completed Inspections
Case Status: COMPLIAN
Case Number: T03DV01222
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2003 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VISITED SITE, NO CONTACT HAS BEEN MADE BY OWNER BEFORE INSPECTION. WALKED UNIT WITH TENAT. CHECKED BASE BOARD HEATERS. 4121 (1) LIVING RM. BASE BOARD HEATER NOT PUTTING OUT ADAQUATE AMOUNT OF HEAT. (2) NORTHWEST BED RM. BASE BOARD HEATER NOT PUTTING OUT ADAQUATE AMOUNT OF HEAT. (3) NORTHEAST BASE BOARD HEATER WORKING PROPERLY. (4) REQUIRE THRESHOLD AND WEATHER STIPPING LACKING FOR ENTRY DOOR. (5) SMOKE DETECTORS CHECKED & FOUND TO BE WORKING. (6) CHECKED ALL WINDOWS FOUND 1-WINDOW CRANK NOT WORKING IN N.W. BEDROOM. (7) CHECKED G.F.I.C. OUTLETS IN KITCHEN & WERE IN GOOD OPERATING CONDITION. (8) GAS STOVE IGNITORS NOT WORKING FOR RANGE TOP & OVEN GAS VALVE WILL NOT OPEN. (9) REAR ENTY DOOR HARD TO OPEN & ONLY HAS THUMB THOW TO OPEN DOOR & LACKING WEATHER STRIPPING. INSPECTION OF EXTERIOR FOUND SIGN OF POSSABLE WORK WITH OUT PERMIT & INSPECTION. STRUCTURE ACCORDING TO TENANT WAS TOLD STRUCTURE WAS ONCE 1 DWELLING THAT HAS BEEN ENVERTED INTO DUPLEX. FOUND WATER LINES HAVE BEEN ADDED, 2 SEPERATE GAS METERS ELECTRICAL UP-GRADE FOR BOTH STRUCTURES. ADDITION OF PORCH 2''X6'' TO RAFFTER AND NOT SUPPORTED PROPERLY AND MISSING LEAGER & BRACKETS TO MAIN STRUCTURE APPROX 8''X30. ADDITION AND MODIFICATION TO EXISTING PLUMBING VENT STACK DOSE NOT EXTEND PASS ROOF LINE, WATER LINE NOT SECURED TO WALLS. (10) RIDGE VENT LACKING AT NORTHSIDE OF STRUCTURE. (11) ADDITION OF ELECTRICAL CIRCUITS FROM UP-GRADE PANELS. VIOLATIONS FOUND AT 4123. (1) WEST ENTRY DOOR LACKING REQUIRED TRESHOLD & WEATHER STIPPING. SPOKE WITH TENANT AND ALLOWED ENTRY INTO STRUCTURE TO CHECK HEATER SYSTEM. UNIT ALSO HAS BASE BOARD HEATERS INSTALLED IN 2 BEDROOM & LIVING ROOM. WAS UNABLE TO CONTINUE INSPECTION DUE TO TENANT HAVING TO LEAVE, ASKED IF INSPECTOR COULD MAKE ARRANGEMENTS FOR REMINDER OF INSP. & STATED HE WOULD BE LEAVING OUT OF TOWN. TENANT DRIVES FOR A LIVING (TRUCKER) HAD RIG PARKED & RUNNING ON STREET. STATED TO CONTACT OWNER TO COMPLETE INSP. WILL ISSUE N.O.V. FOR BASE BOARD HEATERS TO BE REPAIRED WITH IN 5 DAYS & ISSUING OF REMAINING VIOLATION TO FOLLOW. WILL DO RESEARCH ON POSSABLE WORK WITH OUT PERMITS & TAKE STEPS WHEN COMPLETED. |
| 10/14/2004 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | VIOLATIONS WERE ABATED AS PER REQUEST OF N.O.V. WENT OVER CASE WITH INSP II RICK SALDATE, OTHER ITEM LISTED IN NOTES DO NOT PERTAIN TO I.R.C. CODE BOOK. CLOSE CASE PER RICK S. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01222
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 10/15/2004 | NOTICE OF VIOLATION ISSUED |
| 10/15/2004 | VIOLATION CLOSED |