Case: T03DV01215
Case Details
Entered Date:
12/17/2003
Applicant:
RAYMOND MARTINEZ
Description:
COMPLAINT:NO HEATER
Outstanding Inspections
Case Number: T03DV01215
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/18/2003 | INSP - INITIAL CODE ENFORCMENT | JHURD | Correction Required | 12/16/03, VISITED SITE, TOOK PICTURES, RESIDENT IS SPANISH SPEAKER, INSP. LOPEZ DID ACCOMPANY ME ON INSP. TO TRANSLATE, UPON INSP. DID FIND SEVERAL MIN. HOUSING ISSUES, UPON ARRIVAL DID FIND OVER GROWN WEEDS IN FRONT AND REAR YARDS, PAINT PEELING AND CHIPPING AND HAS EXPOSED WOOD ALL THE WAY AROUND THE STRUCTURE AND ON FRONT PORCH, HAS INTERIOR CONVENIENCE OUTLET INSTALLED ON EXTERIOR OF STRUCTURE FRONT SIDE, FRONT DOOR WEATHER STRIPPING DETERIORATED AND OR MISSING DOES NOT SEAL PROPERLY, ALLOWS LIGHT TO SHOW THROUGH SIDE, TOP ,BOTTOM, B/R NORTHWEST (MASTER) WINDOW CRANKS ARE BROKEN, WINDOWS DO NOT OPERATE AS INTENDED, NORTHEAST B/R, WINDOW CRANKS ARE BROKEN AND OR MISSING, WINDOW CRANKS THROUGH OUT ARE BROKEN AND OR ARE MISSING HANDLES, 3 PRONG CONVENIENCE OUTLETS THROUGHOUT SHOWS OPEN GROUND UNDER TEST, UNIT HAS NO SMOKE DETECTOR, BATH ROOM LIGHT FIXTURE HAS 3 PRONG CONVENIENCE OUTLET, NOT GFCI PROTECTED, KITCHEN CONVENIENCE OUTLET NOT GFCI PROTECTED WITHIN 6' OF PLUMBING FIXTURE, KITCHEN SINK HAS 2 LEAKS UNDER FIXTURE, ONE AT DRAIN LINE AND ONE AT COLD WATER ANGLE STOP, ELECTRICAL SUB-PANEL IS NOT SITTING FLUSH WITH WALL DUE TO ELECTRICAL WIRE INSTALLED AND COMMING OUT FROM THE BOTTOM FOR DRYER RECEPTICLE, DRYER RECEPTICLE ADDED, EXPOSED WIRING, RECEPTICLE NOT MOUNTED TO WALL AND OR IS NOT SECURED IN ANY WAY JUST LAYING ON THE BACK OF THE WASHER, COLD WATER EMERGENCY SHUT OFF TO HOT WATER TANK BROKEN, FLUE PIPING TO HOT WATER TANK AND TO HEATER IN NEED OF RESEALING AT CONNECTION JOINTS, HEATER NOT WORKING AT ALL, RESIDENT STATES THAT SOME ONE DID COME BY TO START HEATER BUT RESIDENT STATED THEY SMELLED GAS, TURNED OFF HEATER BECAUSE OF BEING SCARED, ALSO HEATER ON INTERIOR OF CABINET IS DIRTY AND EVIDENCE OF LACK OF MAINTENANCE, BACK DOOR WINDOW DOES NOT SEAL PROPERLY AND ALLOWS ELEMENTS TO ENTER LIVING SPACE, EXTERIOR FENCING DILAPIDATED AND FALLING ON EAST SIDE AND REAR, STRUCTURE HAS 2 NEW METER BOXES INSTALLED, UPGRADED, WILL DO RESEARCH FOR PERMITS, |
| 12/22/2003 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Correction Required | 12/19/03, REVISITED SITE, POSTED OWNERS HOUSE AS REQUESTED BY OWNER RAYMOND MARTINEZ, TOOK PICTURE OF POSTING, |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01215
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 10/14/2004 | CONTACTED BY PHONE |
| 01/07/2004 | NOTICE OF VIOLATION ISSUED |
| 01/07/2004 | COURT ORDERED ABATEMENT |
| 11/04/2004 | VIOLATION CLOSED |
| 12/18/2003 |