Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

12/04/2003

Applicant:

SCHACKART GAIL L

Description:

COMPLAINT:MIN HOUSING-MISSING INTERIOR CONDUIT. GAS LINES FOR DRYER IS NOT SECURED TO HOUSE.

Outstanding Inspections

Case Number: T03DV01174
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
12/17/2003 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 12/16/03, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT ON SITE, DID SEE AN ADDITION W/ ELECT.TO STRUCTURE, (RESEARCH) WALKED AROUND OUTSIDE OF STRUCTURE FOUND WHERE GAS LINE IS NOT SECURED TO STRUCTURE, ADDED 220 ELECTRIC LINE, OPEN AND EXPOSED UNDER 8', ELECTRIC LINE AND JUNCTION BOX NOT SECURED TO STRUCTURE, CONVENIENCE OUTLET UP TOWARD TOP UNDER EAVE NOT WEATHER PROTECTED, SOUTHWEST B/R HAS WROUGHT IRON SECURITY GBARS ON B/R WINDOW NOT AN APPROVED TYPE, DOES NOT BREAK AWAY FOR RAPID EGRESS, SHED SOUTHWEST CORNER OF STRUCTURE IS RIGHT ON PROPERTY LINE, (SET-BACK), FRONT DOOR IS HOLLOW CORE DOOR HAS SMALL HOLE IN DOOR, WEATHER STRIPPING ON FRONT DOOR DETERIORATED AND OR MISSING ALLOW LIGHT AND ELEMENTS TO ENTER LIVING SPAACE, ALSO THRESHOLD AND DOOR SWEEP ALLOWING NOT SEALING PROPERLY, ALLOWING LIGHT AND ELEMENTS TO ENTER LIVING SPACE, MASTER BEDROOM MISSING VENT REGISTER, ELECTRICAL SYSTEM HAS 3 PRONG OUTLETS SHOWS OPEN GROUND THROUGH OUT, HOT WATER TANK MISSING PRV DRAIN LINE, GAS FORCED AIR HEATER IS VERY DIRTY AND FLAMES BACK LASHES FROM CHAMBERS, FLUE PIPE NEEDS SEALING AROUND JOINTS, ALSO HAS FLEX LINE GOING INTO HEATER CABINET, WILL NEED TO BE HARD PIPED THROUGH CABINET, NORTH WEST B/R MISSING COVER PLATES, KITCHEN AND BATH NOT GFCI PROTECTED, REAR DOOR ON ADDITION HAS DOUBLED KEYED DEAD BOLT, ADDITION IS MISSING COOLER FROM ROOF HAS OPENING NOT WEATHER PROTECTED, NORTHEAST B/R HAS FLOURESENT TUBES LIGHT FIXTURE FOR LIGHT TUBES WILL NEED TO BE PROTECTED,

Completed Inspections

Case Status: COMPLIAN
Case Number: T03DV01174
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
10/29/2004 INSP - FOLLOW UP CODE ENFORCE JHURD Approved 5/11/04, REVISITED SITE, PERMITS HAS BEEN SECURED AND FINALED. CLOSE CASE NO JURISDICTION. 2 CONVENIENCE OUTLETS SHOW OPEN GROUND UNDER TEST, BUT D.S.D. DAN QUINN FINALED PERMIT FOR ELECTRICAL. CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01174
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
04/01/2004 CONTACTED BY PHONE
03/08/2004 CONTACTED IN PERSON
01/14/2004 NOTICE OF VIOLATION ISSUED
01/14/2004 COURT ORDERED ABATEMENT
10/29/2004 VIOLATION CLOSED

Documents

File Name Document Type  
MVC-767S.JPG IMAGES VIEW
MVC-768S.JPG IMAGES VIEW
MVC-769S.JPG IMAGES VIEW
MVC-770S.JPG IMAGES VIEW
MVC-771S.JPG IMAGES VIEW
MVC-772S.JPG IMAGES VIEW
MVC-773S.JPG IMAGES VIEW
5958 E 34TH ST.PDF DOCUMENTS VIEW