Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/02/2003

Applicant:

LINDA CURTIS

Description:

COMPLAINT:MIN HOUSING-HOLES IN WALLS

Outstanding Inspections

Case Number: T03DV01169
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
12/02/2003 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 11/20/03, VISITED SITE, TOOK PICTURES, NO ONE HOME AT 3524, AS LOOKING AROUND FOUND IN REAR OF PROPERTY ANOTHER UNIT IN BACK UNDER REPAIRS, UNIT IN BACK IS BEING ADDED ON TO, HAS STUCCO WIRING INSTALLED HAS NOT BEEN STUCCOED AS OF YET, LOOKED INTO WINDOW AND COULD SEE IT IS SET UP AS RENTAL, ALL FACILITIES, KITCHEN, BATH, ELECTRIC AND PLUMBING, DO NOT BELIEVE AT THIS TIME IT HAS BEEN PERMITED, ALSO UNIT 3524 HAS HAD WHAT APPEARS TO BE A BEDROOM ADDED, LAUNDRY ROOM ADDED, 2X4 ROOF STURCTURE, NEED TO DO RESEARCH ON PROPERTY, AS TALKING TO SAM RESIDENT IN 3518 ASKED IF HE HAD ANY PROBLEMS IN HIS UNIT HE STATED YES AND I ASKED IF I COULD GO IN HE STATED YES, SAM AND WIFE SHOWED ME AROUND AND SHOWED WHERE HAS A LEAK IN BATHROOM, SHOWER HEAD DRIPPING ALSO, CAULKING SEPERATING AND CRACKING FROM TILES, WOOD BASE MOULDING SHOWS EVIDENCE OF TERMITES AND IS DETERIORATING FROM WATER LEAK, REAR DOOR HAS DOUBLED KEYED DEAD BOLT INSTALLED, UNIT LACKS REQUIRED SMOKE DETECTOR, EVIDENCE OF ROOF LEAK BY RETURN VENT IN LIVING ROOM, RESIDENT STATES THAT YES IT LEAK ON LAST RAIN, LIVING ROOM FRONT DOOR JAMB IS LOOSE FROM STRUCTURE, NO GFCI PROTECTION IN KITCHEN OR BATH, FOUND ON EXTERIOR OF BUILDINGS, 3524 HAS A/C INSTALLED ON EAST SIDE, HAS DRY ROTTED ELECTRICAL WIRING FROM EXPOSURE TO THE SUN, COOLER IN REAR OF 3524 IS HELD UP BY CHAINS COMMING FROM ROOF EAVE, HAS NO STAND UNDER COOLER, ALSO ADDED ELECTRICAL WIRING TO CONVIENCE OUTLET AND COOLER, CONVENIENCE OUTLET HAS PLUG MISSING ON EAST END, STUCCO BEING ADDED TO REAR STRUCTURE WILL NEED TO HAVE PERMIT SECURED GOING OVER WOOD, PROPERTY HAS ONE GAS METER, ONE WATER METER, THESE UTILITIES ARE IN OWNERS NAME, ELECTRIC IS ISOLATED ALL UNITS HAS THERE OWN METERS, ELECTRICAL PANEL BOX ON WEST SIDE OF REAR STRUCTURE IS LOOSE FROM STRUCTURE, A/C ADDED TO REAR STRUCTURE HAS EXPOSED WIRING AND CONVENIENCE OUTLET HAS BEEN ADDED, HOT WATER TANK IS SETTING IN FRONT YARD, WILL NEED PERMIT TO RECONNECT, WATER LINES ADDED, SEWER VENTS ADDED, WILL DO RESEARCH ON PROPERTY, THEN DO N/O
12/02/2003 INSP - FOLLOW UP CODE ENFORCE JHURD Correction Required 12/2/03, MET WITH OWNER LINDA CURTISS ON SIGHT, WENT OVER ISSUES ABOUT UNIT IN REAR BEING USED AS RENTAL, TALKED ABOUT NO PERMITS ON FILE FOR SUCH STRUCTURE, ALSO NEW STUCCO WOULD NEED TO BE PERMITED, LINDA STATED THAT UNIT HAS BEEN FOR EVER, STILL THERE ARE NO PERMITS FOR SUCH STRUCTURE, LIVING ROOM CEILING UNDER 7', ALSO UNIT 3524 HAS HAD ADDITION BUILT IT IS A BEDROOM, THIS ADDITION HAS NO HEAT, EGRESS WINDOWS ARE NOT ADEQUATE, TO SMALL, HAS ELECTRIC, THIS STRUCTURE HAS BEEN SPLIT IN HALF MAKING IT A DUPLEX, NO PERMITS ON FILE FOR SUCH SPLITING, ONLY OTHER PROBLEM IN UNITS SEEMS TO BE IN THE ELECTRICAL SYSTEM BLOWING FUSES,

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01169
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
09/08/2004 CONTACTED BY PHONE
02/06/2004 CONTACTED IN PERSON
01/06/2004 NOTICE OF VIOLATION ISSUED
01/06/2004 COURT ORDERED ABATEMENT
12/02/2003