Case: T03DV01089
Case Details
Entered Date:
11/12/2003
Applicant:
FISCHELLA MICHAEL F & JOANN C 33
Description:
COMPLAINT:MIN HOUSING- NEWLY INSTALLED HEATER IS OVERLOADING CIRCUIT BREAKERS
Outstanding Inspections
Case Number: T03DV01089
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2004 | INSP - FOLLOW UP CODE ENFORCE | RCAMACHO | Correction Required | MET WITH RICK S. IN OFFICE. DECISION REACHED TO CLOSE CASE. ALL MINIMUM HOUSING VIOLATIONS REMAIN ABATED. PERMIT # T03CM00729 WAS INSPECTED BY CHUCK WILLIAMS (DSD MECH. INSPECTOR) ON 2/19/04. INSPECTION DENIED DUE TO OVERLOAD IN 30,00 BTU UNIT MAX SIZE 30 AMPS. AN ELECTRICAL PERMIT WILL BE REQUIRED TO COMPLY. CASE TO BE CLOSED DUE TO DSD HAVING JURISDICTION OVER PERMIT PROCESS. ALL MINIMUM HOUSING VIOLATIONS REMAIN ABATED. COMPLIANCE. |
| 11/21/2003 | INSP - INITIAL CODE ENFORCMENT | RCAMACHO | Correction Required | INITIAL MET WITH TENANTS ON SITE. FOUND: -OVERHANGS PEELING AND FLAKING PAINT OVER 50%. FRONT ENTRY FIXTURE HANGING FROM WIRING. -NEW CIRCUIT ADDED TO SUBPANEL IN KITCHEN FROM HEAT PUMP ON ROOF. -SMOKE DETECTORS IN BEDROOMS MISSING.(2) -LATTICE AT FRONT PORCH FALLING. -FRONT ENTRY DOOR LACKS REQUIRED W/S AND THRESHOLD. DOOR JAMB IN NEED OF REPAIR. HOLE IN DOOR. - LIVING ROOM WALL AT OPENING HOLES IN PLASTER. - CONVENIENCE OUTLET COVERS MISSING IN LIVING ROOM AND BEDROOM. - HOLE IN LIVING ROOM CEILING AT FLUTE FROM PAST FIRE PLACE. - ROOF LEAK AT BEDROOM CEILING. PLASTER FALLING FROM CEILING. -NEW HEAT PUMP INSTALLED ON ROOF. POSSIBLE W/O PERMIT. POSIBLE ELECTRICAL OVERLOAD TO 60 AMP SERVICE. -LAUNDRY HOT WATER FIXTURE TO WASHING MACHINE LEAKS AT HOSE BIB. -PLASTER FALLING AT NORTH WALL BY WATER HEATER AND WASHING MACHINE IN NEED OF REPAIR. LARGE HOLES IN PLASTER. - CONVENIENCES OUTLETS AT EXTERIOR OF LAUNDRY ROOM NOT OF APPROVED TYPE. -NEW CIRCUIT ADDED TO DRYER APPLIANCE IN KITCHEN. - KITCHEN SINK LEAKS AT FIXTURE AND TRAP. -HOLE IN EXTERIOR WALL UNDER KITCHEN CABINET TO LAUNDRY ROOM. -BATHROOMN WINDOW DOES NOT OPEN FOR REQUIRED VENTILATION. - BROKEN WINDOW GLASS IN LIVING ROOM AND KITCHEN WINDOWS. CONTACTED NANCY WHILE ON SITE. NO PERMITS FOR HEAT PUMP OR DRYER CIRCUIT INSTALLED. SEND NOTICE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01089
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 11/28/2003 | NOTICE OF VIOLATION ISSUED |
| 11/28/2003 | COURT ORDERED ABATEMENT |