Case: T03DV01054
Case Details
Entered Date:
10/30/2003
Applicant:
FOXALL LARRY R
Description:
COMPLAINT:MIN HOUSING-MICE INFESTATION. CEILING LEAKS
Outstanding Inspections
Case Number: T03DV01054
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2004 | INSP - FOLLOW UP CODE ENFORCE | RCAMACHO | Correction Required | FOLLOW UP INSPECTION FOUND: WEATHER STRIP INSTALLED ON BOTH EXTERIOR DOORS FRONT AND REAR. EXPOSED ELECTRICAL REMOVED FROM FRONT PORCH AREA. WALL HEATER PROPERLY SERVICED. ELECTRICAL ISSUES TO INCLUDE LACK OF EXHAUST FAN IN BATHROOM AND EXPOSED WIRING TO STOVE EXHAUST FAN WILL BE ADDRESSED UNDER EXISTING PERMIT. ALL MINIMUM HOUSING VIOLATIONS HAVE BEEN ABATED AT THIS TIME. REMAINING VIOLATIONS WILL BE ADDRESSED UNDER PERMIT. COMPLIANCE. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T03DV01054
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2004 | INSP - INITIAL CODE ENFORCMENT | RCAMACHO | Approved | MET WITH OWNER (SCOTT) ON SITE PER HIS REQUEST. INITITAL INSPECTION OF UNIT #2. FOUND: EXPOSED WIRING AT FRONT ENTRY DOOR LIGHT FIXTURE TO EXTERIOR WALL OF ARIZONA ROOM. FRONT AND REAR EXTERIOR DOORS LACK REQUIRED WEATHER STRIPS. WALL HEATER IN LIVING ROOM HAS NOT BEEN MAINTAINED IN A SAFE WORKING CONDITION. SMOKE DETECTOR IN MASTER BEDROOM DOES NOT OPERATE. NO SMOKE DETECTOR IN REAR ADDITION BEDROOM. MASTER BEDROOM WINDOWS DO NOT OPEN CORRECTLY FOR EMEGENCY ESCAPE OR RESCUE. NO EXHAUST FAN IN BATHROOM OR OPERABLE WINDOW FOR VENTILATION. EXPOSED WIRING AT BATH FIXTURE OVER SINK. EXPOSED WIRING AT COOLER SWITCH IN BATHROOM. EXPOSED WIRING TO STOVE EXHAUST VENT WIRING NOT OF AN APPROVED METHOD. (APPLIANCE CORD). REAR BEDROOM ADDITION. INSUFFICIENT WINDOW SIZE FOR SAFE AND RAPID EGRESS. NO PERMIT ON RECORD FOR BEDROOM ADDITION AT REAR. WATER HEATER VENT STACK ON SAME STACK AS WALL HEATER. NOT PROPERLY SEALED. RELIEF VALVE IN PLASTIC PVC. NOT APPROVED METHOD. NEW WATER HEATER HAS BEEN INSTALLED. A PERMIT IS NEEDED FOR REPLACEMENT. BROKEN WINDOW GLASS AT FRONT ENTRY DOOR. WALKED BOTH UNITS WITH OWNER ON VIOLATIONS AND GAVE OWNER A COPY OF DRAWINGS ON RECORD. HE WILL BE SUBMITTING NECESSARY DRAWINGS FOR PERMITS. INSPECTOR HAS STRESSED THE URGENCY OF THE GARAGE BEING CONVERTED INTO A HABITABLE UNIT. BOTH UNITS ARE SERVICED BY THE SAME 60 AMP SERVICE. UNIT #1 HAS POWER DOUBLE LUGGED FROM UNIT #2. WALKED UNIT #1 PER OWNERS REQUEST. SMOKE DETECTORS INSTALLED BOTH BEDROOMS. WENT OVER WINDOW SIZES IN SLEEPING AREAS. MINIMUM 5.7 SQUARE FT OF OPENING NEEDED IN EACH SLEEPING AREA. WENT OVER FURNACE INSTALLED IN LAUNDRY ROOM. WENT OVER 60 AMP SERVICE DOUBLE LUGGING TO FEED THIS UNIT FROM UNIT #2. WENT OVER ALL VIOLATIONS FOUND. OWNER TO INSTALL NEW WINDOWS THIS WEEKEND FOR SAFE AND RAPID EGRESDS FROM SLEEPING AREAS. SEND NOTICE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01054
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 04/27/2004 | NOTICE OF VIOLATION ISSUED |
| 04/27/2004 | COURT ORDERED ABATEMENT |
| 10/13/2004 | VIOLATION CLOSED |
| 02/17/2004 |