Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T03DV00708
Case Details
Entered Date:
08/01/2003
Applicant:
CIOLLI DONALD R
Description:
COMPLAINT:BATH SINK IS CLOGGED.
Outstanding Inspections
Case Number: T03DV00708
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2003 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Correction Required | VISITED SITE. MET OWNER ON SITE WALKED PROPERTY. TENANT HAS BEEN EVICTED ON 08/03/03, AT UNIT 5752 TENANT ALSO WAS EVICTED ON 8/11/03. BOTH UNITS ARE VACANT AND SECURED AT THIS TIME. HOWEVER INSPECTION OF EXTERIOR DID TURN UP VIOLATIONS. 5754 THRESHOLDS AND WEATHERSTRIPPING, WEATHER PROOF OUTLET COVERS LACKING. HOT WATER HEATER TANK LACKING B-VENT. NONE GROUNDED OUTLETS ON EXTERIOR HAS HAD UPGRADE ON DISCONNECTS 5752- COOLER T-STATE HAS EXPOSED ELECTRICAL CONDUCTORS. ALL OUTLETS ARE NONE GROUNDED, UP-GRADE OF ELECTRICAL CONDUCTORS HAS BEEN DONE. GFIC LACKING IN KITCHEN AND BATHROOM. STRUCTURE LACKING REQUIRED SMOKE DETECTOR ALL VIOLATIONS TO BE ABATED WITHIN 30 DAYS. NOV TO BE ISSUED. |
| 09/29/2003 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Correction Required | VISITED SITE AND MET WITH OWNER, NEW THRESHOLDS AND WEATHER STRIPPING HAS BEEN INSTALLED, WEATHER PROOF COVERS INSTALLED, NEW B-VENT FOR HOT WATER HEATER. ELECTRICAL CONTRACTOR WORKING ON ONE GROUNDED. OUTLETS AND SHOULD BE DONE WITHIN THE WEEK. UNIT ADDRESS 5754. ADDRESS 5752-EXPOSED ELECTRICAL HAS BEEN REMOVED AND NEW T-STAT HAS BEEN INSTALLED, NEW GFIC OUTLETS HAVE BEEN INSTALLED ALONG WITH SMOKE DETECTORS. ELECTRICAL CONTRACTOR WILL HAVE OUTLETS CORRECTED WITHIN THE WEEK. DO FOLLOW UP IN 30 DAYS. NO NOV WAS ISSUED DUE TO BACK LOG AND ONLY 1-VIOLATION REMAINING TO BE ABATED. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00708
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 11/12/2003 | CONTACTED BY PHONE |
| 11/12/2003 | PERMIT ISSUED - T03EL01725 |