Description:

COMPLAINT:MIN HOUSING-COOLER NOT WORKING

Outstanding Inspections

Case Number: T03DV00651
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
07/18/2003 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 7/15/03, CALLED RESIDENT BY PHONE AND DID TALK WITH HER FOR A COUPLE MINUTES AND SHE HAD STATED THAT HAS BEEN HAVING PROBLEMS WITH COOLER AND HAS NOT WORKED SINCE 7/1, BUT DID COME OUT YESTERDAY AND WORKED ON COOLER, DID SAY IT'S BETTER TODAY THAN HAS BEEN BUT STILL NOT COOLING VERY MUCH, I DID VISIT PROPERTY SAME DAY, AND FOUND COOLER WAS BLOWING SOME COLD AIR BUT NOT IN ALL ROOMS, AND COOLER WAS LEAKING FROM ROOF, DID TAKE TEMPERATURE READINGS IN ALL ROOMS AND FOUND THAT LIVING ROOM WAS AT 88 DEGREES, KITCHEN WAS AT 86 DEGREES, MASTER B/R 89 DEGREES, 2ND B/R (BABY'S ROOM) 93 DEGREES AND NO AIR WAS COMMING FROM THAT REGISTER, AS LOOKING AROUND CHECKED FURNANCE ROOM AND THAT ALOT OF COOLER AIR WAS COMMING FROM A HOLE IN CEILING, APPEARS THAT COOLER IS LOSING AIR INTO CEILING SPACE, BROKEN DUCT WORK OR HAS HOLE IN DUCT WORK SOME REASON TO BE LOSING AIR BEFORE GETTING TO REGISTERS, WILL TALK WITH OWNER. N.O. TO FOLLOW, ALSO FOUND ADDED ELECTRICAL 220 CIRCUIT FOR DRYER INSTALL IN STORAGE ROOM, AND CONVENIENCE OUTLET ADDED IN STORAGE ROOM, DOES NOT APPEAR TO BE AN IMMENT HAZARD AT THIS TIME, I COULD NOT GET ELECTRICAL PANEL BOX OPEN AT THIS TIME TO SEE IF ANY DOUBLE LUGGING WAS IN PLACE WILL DO ON FOLLOW UP,

Completed Inspections

Case Status: VOID
Case Number: T03DV00651
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
10/15/2003 INSP - FOLLOW UP CODE ENFORCE JHURD Approved 10/10/03, FOUND UNIT TO BE VACATED BY RESIDENT, HAS FOR RENT SIGN IN FRONT YARD, KNOCKED ON DOOR NO ONE ANSWERED, PICTURES IN FILE, CLOSE CASE DUE TO VACANT UNIT, CLOSE CASE

Outstanding Case Activity Conditions

Date Name Approved
07/18/2003 Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00651
Case Status: VOID
Total Completed Case Activity Conditions: 1
Date Name
07/21/2003 NOTICE OF VIOLATION ISSUED