Case: T03DV00617
Case Details
Entered Date:
07/09/2003
Applicant:
FULLER JERRY D
Description:
COMPLAINT:MIN HOUSING-CEILING FALLIN DOWN
Outstanding Inspections
Case Number: T03DV00617
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/09/2003 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Violation | NOV ISSUED HAND DELIVERED VISITED SITE, MADE CONTACT WITH TENANT, WALKED STRUCTURE . VIOLATIONS FOUND ARE AS FOLLOWS. HAZARDOUS ELECTRICAL (1) OUTLETS MISSING COVER PLATES. (2) ADDITION OF 220 CIRCUIT FOR DRYER & LACKING COVER PLATE (3) ILLEGAL USE OF EXTENTIONS CORD IN LIEU OF PERMINENT ELECTRICAL CIRCUIT FOR WASHING MACHINE. (4) UNGROUNDED RECEPTACLES & REVERSED HOT NETURALS RECEPTACLES THOUGH OUT STRUCTURE. (4) GFIC RECEPTACLES LACKING IN KITCHEN AREA. (5) ORGINAL ELECTRICAL SERVICE HAS BEEN ALTERED. EVIDENCED BY NEW MAST HAS BEEN INSTALLED AND CONNECTION IS MORE THAN 24 INCHES LONG & ALLOWING SERVICE DROP TO BE ACCESSABLE. (6) CEILING LIGHT FIXTURE HAS BEEN DAMAGED & WILL REQUIRE REPLACEMENT FIRE SAFETY (1) STRUCTURE LACKING SMOKE DETECTORS. (2) EXTERIOR BACK DOOR COMING AWAY FROM HINGES. WEATHER PROOFING (1) ALL ENTRY DOORS LACKING WEATHER PROOFING. (2) COOLER SUPPLY LINE HAS DAMAGED ROOF & LEAK HAS CAUSED BEDROOM CEILING TO COLLASPE. (3) SEVERAL WINDOWS WERE FOUND BROKEN THOUGH OUT STRUCTURE. STRUCTURAL- W/O/P (1) PORCH STRUCTURE IS IN A DELAPTATED STATE, IMPROPERLY ATTACHED TO MAIN STRUCTURE. 2 BY 4 SCABED TOGETHER & LACKING PROPER HARDWARE. (2) ROOM ON NORTH WEST CORNER MAY HAVE BEEN ADDITION TO MAIN STRUCTURE. BATHROOM WITH SHOWER CLOSET IN NORTH SIDE HAS OLD DRAIN & IS EVIDENCE OF REMODEL. WILL CHECK FOR PERMITS. (3) EXTERIOR PLASTERED WALL SHOWS SIGNS OF DETERIOATION, SOUTH WEST CORNER HAS 3/8 OF AN INCH CRACK RUNNING FROM TOP TO BOTTEM. ASKED TENNAT IF THERE WAS ANY PROBLEMS WITH ROACHES & OR MICE, TENANT REPLIED NO PROBLEMS WITH EITHER. PLUMBING SYSTEMS (1) HOT WATER TANK LACKING COLD WATER SHUT OFF. (2) HOT WATER TANK LACKING B-VENT SYSTEM. (3) COOLER SUPPLY LINE LEAKING & HAS CAUSED A SECTION APPROX. 4 FOOT BY 4 FOOT OF BEDROOM CEILING TO COLLASPE. MECHANICAL SYSTEMS (1) COOLER LACKING PROPER COOLER STAND (2) LACKING COOLER VENT REGISTER IN BEDROOM. HEATING SYSTEMS (1) NO PERMINENT SOURCE OF HEATING IN STRUCTURE. CONTACTED OWNER, REQUESTED REPAIR PERSONAL TO ABATE WATER LEAK FROM COOLER INTO BEDROOM. OWNER STATED LEAK WOULD BE ADDRESSED BY END OF DAY. 7/9/04. INFORMED HER NOV FOR OTHER VIOLATIONS WOULD BE FOLLOWING AFTER RESEARCH WAS COMPLETED. ISSUED NOV FOR DETERIORATED ROOF HAS ALLOWED WATER TO PENATRATE INTO CEILING & CAUSE SECTION OF CEILING TO COLLASPE & LEAKING COOLER SUPPLY LINE. 24 HRS WERE GIVEN. PICTURES WERE TAKEN. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T03DV00617
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/01/2003 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | STRUCTURE VACANT & SECURED. VISITED SITE STRUCTURE IS VACANT & SECURED AT THIS TIME. CONTACTED OWNER, OWNER HAVING FINANCIAL PROBLEMS & CAN NOT AFFORD REPAIRS TO STRCTURE AT THIS TIME, INFORMED OWNER STRUCTURE MUST PASS MIN-HOUSING INSPECTION BEFORE REOCCUPING STRUCTURE. DO 60 DAY FOLLOW UP. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00617
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 01/06/2005 | CONTACTED BY PHONE |
| 06/02/2004 | NOTICE OF VIOLATION ISSUED |
| 06/02/2004 | COURT ORDERED ABATEMENT |
| 03/03/2005 | VIOLATION CLOSED |
| 05/25/2004 | TENNAT CONTACTED INSP. BY PHONE |
| 05/25/2004 | OWNER CONTACTED INSP. BY PHONE |
| 05/25/2004 | CONTACTED INSP. II RICK SALDATE IN PERSON |