Case Details

Status:

VOID

Type:

RES: MINIMUM HOUSING

Entered Date:

05/16/2003

Applicant:

PHELPS RUBY ANN

Description:

COMPLAINT:MIN HOUSING:TFD/FIRE DAMAGE

Case Violations

Case Number: T03DV00436
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date Code Statue
05/21/2003 NOTICE OF VIOLATION ISSUED

Completed Inspections

Case Status: VOID
Case Number: T03DV00436
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/20/2003 INSP - INITIAL CODE ENFORCMENT JHURD Approved 5/16/03, WAS CALLED TO THIS SITE BY INSP. 2 RICK, APPOX I:00 PM DUE TO A FIRE, UPON ARRIVING T.F.D. WAS STILL ON SITE, MET WITH CHRIS KELAHER CAPT. OF ENGINE 14, MR KELAHER SHOWED ME AROUND AND WENT OVER WHAT HAD HAPPENED, AS TALKING WITH MR KELAHER I SAW WHERE THE FIRE HAD DESTROYED THE ELECTRICAL SYSTEM, SEVERAL HOME RUNS COMING FROM ELECTRICAL PANEL GOING INTO THE HOUSE HAS BEEN MELTED TOGETHER, THIS WILL NOT ALLOW THE ELECTRIC POWER TO BE RESTORED UNTIL ELECTRICAL WORK HAS BEEN COMPLETED, RUBY ANN PHELPHS (OWNER) WAS ON SITE, DID WALK RUBY AROUND AND SHOWED HER THE PROBLEMS, I TALKED WITH RUBY AND EXPLAINED WHY I WOULD BE SHUTTING DOWN HER HOUSE AND SHE DID UNDER STAND, ALSO TALKED WITH RUBY ABOUT THE SECURING OF HER HOUSE AND SHE DID GET A HOLD OF HER INSURANCE CO. AND THEY DID SEND OUT A CLAIMS ADJUSTER, CLAIMS ADJUSTER SET UP SECURING OF HOUSE, I TALKED WITH RUBY ABOUT 5 PM AND SHE STATED THAT INSURANCE DID SECURE HOUSE, CITY DEEMS HOUSE UNFIT TO OCCUPY UNTIL ELECTRICAL WIRING HAS BEEN REPAIRED AND OR REPLACED, UNDER PERMIT, ASSESSMENT OF FIRE DAMAGE TO INCLUDE, ENTIRE STORAGE SHED COMPLETE LOSS, ELECTRICAL PANEL (MAIN) MINIMALLY DAMAGED BUT HOME RUN WIRES ARE COMPLETELY BURNED AND WILL NEED TO BE REPLACED, HOT WATER HEATER DESTROYED DUE TO HEAT AND GAS LINES WILL NEED TO BE LOOKED AT, REAR PORCH HEAVILY BURNED WITH BEAMS, JOIST, AND SHEATHING NEEDING TO BE REPLACED, BOTH BATHROOMS SHARE I WALL WITH STORAGE ROOM AND WILL REQUIRE REPAIR INCLUDING WIRES TO LIGHT AND RECEPTICLE CIRCUIT, KITCHEN, DININGROOM, BEDROOM, AND BOTH BATHROOMS HAVE DAMAGE TO CEILINGS DUE TO SMOKE AND PROBING FOR HOT SPOTS IN CEILING, NO DAMAGE EVIDENT TO STRUCTURAL MEMBERS BUT ROOF SHEATHING REMOVED COMPLETELY IN SOME AREAS. PLANS AND PERMITS WILL BE REQUIRED FOR REPAIRS.
08/15/2003 INSP - FOLLOW UP CODE ENFORCE JHURD Approved 8/14/03, MET WITH INSP. 2 RICK S. ON CASE OWNER STILL HAS NOT REOCCUPIED UNIT, COMBO PERMIT HAS BEEN ISSUED, # T03CM03102, REPAIR WORK UNDER WAY CLOSE CASE DUE TO OWNER STILL HAS NOT REOCCUPIED UNIT AND PERMIT HAS BEEN ISSUED FOR REPAIRS. CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00436
Case Status: VOID
Total Completed Case Activity Conditions: 1
Date Name
05/18/2009 VIOLATION CLOSED