Case Details

Status:

VOID

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

04/14/2003

Applicant:

ANDERSON RAQUEL P LOPEZ

Description:

COMPLAINT:MIN HOUSING-SHOWER LEAK

Case Violations

Case Number: T03DV00351
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date Code Statue
05/12/2003 NOTICE OF VIOLATION ISSUED

Outstanding Inspections

Case Number: T03DV00351
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
04/30/2003 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 4/18/03, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT SIRN & DEAN THEY HAD SHOWED WHERE THE BATH ROOM SHOWER AREA HAS BEEN LEAKING IN BEHIND THE MARLITE PANELING THAT COVERS THE SHOWER WALLS, MARLITE IS COMMING AWAY FROM THE WALLS AND ALLOWING WATER TO GET IN BEHIND AND DETERIORATE THE WALLS, BATH SINK CABINET ALSO IS DETERIORATING FROM WATER LEAK ON BOTTOM AND SIDE CLOSEST TO SHOWER, CHECKED OUTLET IN BATH AND SHOWS OPEN GROUND AND NOT GFCI. ALSO STATED THAT DID HAVE ROOF LEAK BUT ROOF LEAK HAD BEEN TAKEN CARE OF BUT STILL HAS DRYWALL ISSUES THROUGH OUT UNIT INSIDE, MASTER BEDROOM SHOWS OPEN GROUND, 2ND BEDROOM SHOWS OPEN GROUND, 2ND BEDROOM ALSO HAS BROKEN WINDOW, 2ND BEDROOM ALSO HAS EXPOSED WIRING COMMING OUT OF ELECT. BOX GOING THROUGH WALL TO KITCHEN, ALSO BOX IS IN CLOSET AND ALL FUSES IN FUSE BOX ARE RATED AT 20 AMPS, OVER PROTECTED, USING DISCONNECT BOX AS JUNCTION BOX NOT DISCONNECT, KITCHEN SHOWS OPEN GROUND, KITCHEN WINDOW BROKEN, HEATER DUCT WORK NEEDS SEALING AROUND CONNECTION JOINTS, TEMPERATURE PRESSURE RELIEF VALVE NOT INSTALLED PROPERLY GOES UPWARD INSTEAD OF DOWNWARD AND OUT, LIVING ROOM OUTLETS SHOWS OPEN GROUND, EXTERIOR ELECT. BOX NEEDS TO HAVE VEGETATION CUT BACK TO ACCESS PANEL BOX. HEATER VENT PIPE THAT GOES THROUGH THE ROOF NEEDS TO BE RAISED ABOVE THE COOLER, COMPLAINS ABOUT SEWER BACKING UP ALOT, HAS HAD CURTIS PLUMBING HAD BEEN THERE AND RAN CAMERA STATED THAT LINE NEEDS TO BE REPLACED, GARAGE IN REAR OF PROPERTY DO TAXES OUT OF GARAGE. WILL DO RESEARCH AT D.S.D. TO SEE IF GARAGE IS ON PLANS, N.O. TO FOLLOW.

Completed Inspections

Case Status: VOID
Case Number: T03DV00351
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
07/17/2003 INSP - FOLLOW UP CODE ENFORCE JHURD Approved 7/16/03, REVISITED SITE, FOUND UNIT HAS BEEN VACATED AND TALKED WITH MGMT. WHO STATED THAT THEY DID VACATE RIGHT AFTER MY INSP. WAS DONE, MGMT. STATED THAT MOST WORK DONE AND I HAVE FAX COPIES IN FILE, ELECTRICAL PERMIT HAS BEEN SECURED AND FINALLED, ROOF REPAIR DONE, PLASTER REPAIRED, BATH HAS BEEN RETILED, IS GETTING UNIT READY FOR RERENTAL CLOSE CASE VACATED UNIT NO JURISDICTION.