Case: T02VL02342
Case Details
Entered Date:
11/25/2002
Applicant:
SWIDERSKI STEPHEN JOSEPH JR & SA
Description:
EMERGENCY CALL-OUT: FIRE
Outstanding Inspections
Case Number: T02VL02342
Case Status: CLOSED
Case Description: RES: FIRE
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2002 | INITIAL CODE VIOLATION | MTESTER | Correction Required | EMERGENCY CALL-OUT DUE TO FIRE, OWNERS NOTIFIED, UTILITIES DISCONNECTED (ELECTRIC/GAS), OWNERS SIGNED N&O AND INDEMNIFICATION. DAMAGE ABOVE COMMON WALL OF KITCHEN AND MAIN BATHROOM IN ATTIC, 2 TRUSSES NEED TO BE EXAMINED CLOSELY, WIRING ABOVE THIS AREA DAMAGED POSSIBLE CPVC, PIPING DAMAGED WITH INSULATION. FLEXIABLE DUCT WORK FOR COOLER AND BATH EXHAUST FAN DAMAGED, ALSO DRYWALL IN ALL OF THE ABOVE LOCATIONS, CAUSE OF DAMAGE: FIRE IN ATTIC ABOVE COMMON WALL BETWEEN KITCHEN AND BATHROOM, LOCATION OF DAMAGE: ATTIC, BLDG: CHARRED TRUSSES NEED TO BE ANALYZED BY ARCHITECT OR ENGINEER. DRYWALL IN KITCHEN AND BATHROOM. BATH CEILING, ELECT: WIRING TO RANGE, BATHROOM EXHAUST FAN AND OTHER WIRING CROSSING THIS SPACE, PLUMB: WATER LINES CPVC CHARRED AND INSULATION DESTROYED, MECH: FLEXIBLE DUCT WORK ABOVE BATHROOM AND BATH EXHAUST FAN, FOLLOW UP 1/6/03 |
Completed Inspections
Case Status: CLOSED
Case Number: T02VL02342
Case Description: RES: FIRE
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/19/2003 | FOLLOW UP CODE VIOLATION | JRIVA | Approved | PERMIT #T03CM00231 ISSUED, CLOSE PER JRIVA |
Completed Activity Special Conditions
Case Description - RES: FIRE
Case Number - T02VL02342
Case Status: CLOSED
Total Completed Case Activity Conditions: 1
| Date | Name |
| 11/25/2002 | SITE VISIT/INSPECTION MADE. SEE INSPECTION RESULTS AND NOTATIONS FOR SPECIFIC INFORMATION. |