Case: T02VL02181
Case Details
Entered Date:
10/24/2002
Applicant:
BREWSTER FRANK L & HELEN V JT/RS
Description:
COMPLAINT:SABER
Outstanding Inspections
Case Number: T02VL02181
Case Status: SUSPNDED
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2002 | INITIAL CODE VIOLATION | RCAMACHO | Correction Required | CLOSURE: AFTER SEARCHING RECORDS AT DSD FOUND LARGE ROOM ADDITION AT SOUTH END OF PROPERTY W/O REQUIRED PERMIT. ALSO CONTACTED HEATHER THRALL TROUGH E-MAIL AND FOUND ZONING WILL OPEN A CASE ON ILLEGAL DWELLING FOR TRAVEL TRAILER ON NORTH END OF PROPERTY. WHICH IS BEING RENTED OUT. ALSO HAVE POSTED 30-DAY NOTICE ON TRAVEL TRAILER FOR THE UNSAFE PURPOSE FOR WHICH IT IS BEING USED DUE TO THE FACT OF THE IMPROPER ELECTRICAL CONNECTION TO MAIN SERVICE. ALSO LACKS REQUIRED BATH FACILITIES. MET WITH YVONNE FROM PIMA COUNTY WASTE. HAVE COPY OF SEWER LAY OUT. ALL LEGAL. ALSO HAVE ARIALS THAT SHOW W/O PERMITS ON ADDITION. |
| 11/19/2002 | FOLLOW UP CODE VIOLATION | RCAMACHO | Correction Required | TRAVEL TRAILER AT NORTH END HAS BEEN REMOVED. IS STILL BEING STORED ONLY ON SITE. MET ON SITE WITH OWNER. INITIAL INSP OF INTERIOR COMPLETED. FOUND 8 TOTAL ROOMS USED AS SLEEPING QUARTERS. 2 IN THE MAIN HOUSE ARE NOT NUMBERED. OTHER 6 NUMBERED 1-6. MAIN HOUSE: NO SMOKE DETECTORS SLEEPING ROOMS (2). BATH LIGHT FIXTURE MUST BE GFCI OR DELETED. BED LIES IN PATH OF EMERGENCEY EGRESS. LIVING ROOM DOOR LACKS REQUIRED SWEEP. GAS FURNACE HAS BEEN MOVED. NEEDS PERMIT TO RE-CONNECT. EXHAUST STACK LOOSE. IMPROPER WIRING TO FOUNTAIN FROM PANTRY. GFCI OUTLET LACKING OVER PANTRY SINK. ILLEGAL LIGHT FIXTURE AT SHOWER CEILING. GFCI OUTLET NEEDED OVER BATH SINK. EXTENSION CORD MUST BE REMOVED AT BEDROOM. SMOKE DETECTOR DOES NOT OPERATE. ALL EXPOSED EXTERIOR AND INTERIOR WIRING MUST BE PROPERLY COVERED TO PREVENT PHYSICAL DAMAGE OR DELETED. EXTERIOR GAS LINE MUST BE PROPERLY SECURED TO FURNACE. UNIT #1: WINDOW A/C UNIT BLOCKS EGRESS. CONVENIENCE OUTLET COVERS MISSING. NO EXHAUST FAN IN BEDROOM. UNIT #2: DANGEROUS SUB-PANEL BY WALL HEATER. REGISTER AT COOLER VENT MISSING. CONVENIENCE OUTLETS MISSING. NO SMOKE DETECTOR. UNIT #3: NO SMOKE DETECTOR. GFCI OUTLET LACKING OVER BATH SINK. SHOWER AREA HAS NOT BEEN MAINTAINED IN A NON-ABSORBENT MANNER. DOOR DOES NOT OPERATE PROPERLY. POOL: CANOPY 12' X 20' AT POOL OVER 200 SQ FT WITH ELECTRICAL MAY REQUIRE PERMIT. POOL ROOM AT REAR HAS EXPOSED WIRING. POOL ENCLOSURE LACKS REQUIRED SELF-CLOSING GATE. UNIT #4: NO SMOKE DETECTOR. DOOR DOES NOT OPERATE PROPERLY. EXPOSED WIRING AT EXTERIOR COOLER SWITCH. UNIT #5 NO SMOKE DETECTOR. CONSTRUCTION IN PROGRESS TO SPLIT ROOM W/O PERMIT. UNIT # 6: EXPOSED WIRING. SMOKE DETECTOR DOES NOT OPERATE. CONVENIENCE OUTLET COVERS MISSING. ILLEGAL LIGHT FIXTURE OVER BATH SINK. COMMODE NOT PROPERLY SECURED TO FLOOR. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 12/20/2002 | NOTICE AND ORDER ISSUED | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T02VL02181
Case Status: SUSPNDED
Total Completed Case Activity Conditions: 1
| Date | Name |
| 08/11/2006 | VIOLATION CLOSED. |