ROOF DAMAGED
Outstanding Inspections
Case Number: T02VL01468
Case Status: CLOSED
Case Description: COM: FIRE
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2002 | INITIAL CODE VIOLATION | LHANLY | Correction Required | AFTER THE FACT DAMAGE REPORT. ROOF FAILURE CHESTNUT CONSTRUCTION @ SITE MAKING EMERGENCY REPAIRS. SUGGEST INVESTIGATION OF TENANT SPACE TO WEST. HOLES KNOCKED IN DEMISING WALL FOR THEIR BEAMS MAY HAVE BEEN CONTRIBUTING FACTOR NEAR SOUTH END APPEAR TO HAVE CAUSED INITAL FAILURE WITH SUBSEQUENT WEDGE ANCHORS THEN FAILING. SUMMARY OF REMARKS CHESTNUT CONSTRUCTION AT SITE INSTALLING ROOF JACKS TO SUPPORT STRUCTURE. FOLLOW UP 8/19/02 |
Completed Inspections
Case Status: CLOSED
Case Number: T02VL01468
Case Description: COM: FIRE
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2002 | FOLLOW UP CODE VIOLATION | AMATHIES | Approved | INSPECTED 8-19 BY ART MATHIESON. |