Case: T01VL02526
Case Details
Entered Date:
09/04/2001
Applicant:
HARPER JOHN A & SUSAN P JT/RS
Description:
EMERGENCY CALL-OUT: CAR INTO BLDG
Outstanding Inspections
Case Number: T01VL02526
Case Status: CLOSED
Case Description: RES: AUTO INTO BLDG
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/01/2001 | INITIAL CODE VIOLATION | DBRITO | Correction Required | EMERGENCY CALL-OUT DUE TO CAR INTO BLDG, NO N&O ISSUED, NOT PICTURES TAKEN, CAUSE OF DAMAGE: CAR INTO BLDG, LOCATION OF DAMAGE: EAST WALL OF STRUCTURE, BLDG: INTERIOR BRG WALL SHIFTED BY IMPACT EXTERIOR WALL CRACKED THRU-OUT BY IMPACT, EXTERIOR MASONARY EAST WALL IMPACT APPROX 18 FEET FROM NORTH EAST CORNER-STRESS FRACTURES TO ROOF IMPACT UNDER RIDGE BEAM. INTERIOR EAST WALL (BEARING) EXTENSIVE DAMAGE AS WELL AS INTERIOR WALL, ELECTRICAL: 3 TO 4 ELECTRIC CIRCUITS MAYBE INVOLVED, PLUMBING: BATHROOM WASTE, VENT AND WATER MAY BE DAMAGED , PERMITS REQUIRED FOR REPAIRS, FOLLOW UP 09/21/2001 |
Completed Inspections
Case Status: CLOSED
Case Number: T01VL02526
Case Description: RES: AUTO INTO BLDG
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/22/2001 | FOLLOW UP CODE VIOLATION | JRIVA | Approved | PERMIT ISSUED, CLOSE |
Completed Activity Special Conditions
Case Description - RES: AUTO INTO BLDG
Case Number - T01VL02526
Case Status: CLOSED
Total Completed Case Activity Conditions: 1
| Date | Name |
| 09/24/2001 | SITE VISIT/INSPECTION MADE. SEE INSPECTION RESULTS AND NOTATIONS FOR SPECIFIC INFORMATION. |