Case Details

Status:

COMPLIAN

Type:

RES: FIRE
Address:

Entered Date:

05/09/2000

Applicant:

HAHN ANNY

Description:

COMPLAINT:EMERGENCY CALL OUT DUE TO FIRE

Outstanding Inspections

Case Number: T00VL00617
Case Status: COMPLIAN
Case Description: RES: FIRE
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
05/08/2000 INITIAL CODE VIOLATION RCHAVEZ Violation VIOLATION

Completed Inspections

Case Status: COMPLIAN
Case Number: T00VL00617
Case Description: RES: FIRE
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/08/2000 FOLLOW UP CODE VIOLATION RCHAVEZ Approved VIOLATION

Completed Activity Special Conditions

Case Description - RES: FIRE
Case Number - T00VL00617
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
12/21/2001 VIOLATION CLOSED.
05/09/2000 05/08/00 SITE VISIT/INSPECTION MADE, DUE TO EMERGENCY CALL BY RCHAVEZ FROM TFD. UTILITIES WERE DISCONNECTED BY TEP ALONG WITH SOUTHWEST GAS. INSPECTION MADE NOT MUCH DAMAGE TO HOUSE, TWO RAFTERS 24" X 24" HOLE IN FLOOR A 12"X12" HOLE MADE IN COMMON FIRE WALL. FURNACE COMBUSTION AND MAKE UP AIR DAMAGED NOT PROPERLY INSTALLED IN UNIT A. UNIT B IS TAKING IN MAKE UP AIR THROUGH BEDROOM DOOR IS NOT AIR TIGHT ALSO HOT WATER HEATER IS LOCATED IN KITCHEN. BOTH FLUE VENTS OBSTRUCTED AND HEAVILY CLUTTERED AROUND EXTERIOR BOTH UNITS. WILL NEED TO OBTAIN A COMBINATION PERMIT TO REPAIR NO FURNACE IN BEDROOMS. CAUSE OF DAMAGE: WATER HEATER FLUE WAS OBSTRUCTED AND WOULD NOT ALLOW GASES TO ESCAPE CAUSING OVER HEATING @ BOTTOM OF HEATER. FLOOR APPROXIMATELY 24" SQUARE HOLE TWO RAFTERS DESTROYED HOLES MADE TO COMMON FIRE WALL BY FIRE FIGHTERS NO ELECTRICAL DAMAGE NO PLUMBING DAMAGE NO MECHANCIAL DAMAGE. WILL NEED TO SECURE A GENERAL REPAIR PERMIT AND GAS, PLUMBING PERMIT. FURNACE IS GETTING GTS MAKE-UP AIR FROM BEDROOMS AND HOT WATER HEATER IS IN KITCHEN WITH VERY LITTLE COMBUSTION AND RELIEF SYSTEM MAY HAVE TO RELOCATE. NOTICE & ORDER SENT TO OWNER VIA CERTIFIED MAIL. RETURNED PACKET TO FILE.
06/06/2000 05/08/00 NOTICE AND ORDER ISSUED: TO OWNER VIA CERTIFIED MAIL. 06/06/00 N&O RETURNED UNCLAIMED SENT REGULAR MAIL. RETURNED PACKET TO FILE. 06/16/00 SENT PROCESS SERVICE.