Case: CE-VIO1222-01147
Case Details
Status:
Closed - Resolved
Type:
DILAP / 2nd level walk way has dilapidated wood caused by water damaged in front of Unit 8
Address:
Entered Date:
12/28/2022
Applicant:
N/A
Description:
Completed Inspections
Case Status: Closed - Resolved
Case Number: CE-VIO1222-01147
Case Description: DILAP / 2nd level walk way has dilapidated wood caused by water damaged in front of Unit 8
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2023 | COT - ENFC - Code Enforcement - Initial | Passed | VISITED SITE, WALKED ALL THE 2ND FLOOR WALKWAYS OF 3 DIFFERENT BUILDING, FOUND SCUPPERS/ WATER COLLECTION BOXES EVENLY SPACED FROM THE CRICKETS THAT DRAIN THE WATER OFF THE ROOF TO THE COLLECTION BOXES. ALL SCUPPERS ARE LOCATED BELOW THE THE ROOF COVERING OF THE 2ND FLOOR WALKWAYS. WATER COLLECTION BOX HAS A DRAIN PIPE THAT RUNS FROM THE BOX DOWN TO THE 1ST FLOOR CONCRETE AND THEN DRAINS ONTO THE PARKING LOT PAVEMENT. THE WALKWAY IS CONSTRUCTED OF 4X6 RAFTERS EVER 16" ON CENTER, USING PROPER HANGERS ON THE LEDGER, SIT ON TOP THE BEAM /POST AND ON TOP OF THE WALKWAY IS LIGHT WEIGHT CONCRETE OVER 3/4 INCH PLYWOOD. CONCRETE WAS TIGHT AGAINST EACH DRAIN PIPE AD THERE WAS NO ROTTING OF PLYWOOD DOWN BELOW. THE WALKWAYS WERE WELL BUILT ROOF HAS PROPER DRAINAGE AS WELL AS THE WALKWAY DECK, WORKMANSHIP IS A LITTLE ROUGH BUT NO DILAPIDATION. FOUND NO WATER LEAKS OR ISSUES. COMPLIANCE / CLOSE CASE. |