Description:

Completed Inspections

Case Status: Closed - Resolved
Case Number: CE-VIO1122-00552
Case Description: EMERG- TFD called out for structural fire
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/18/2022 COT - ENFC - Code Enforcement - Initial In Violation VISITED SITE, MET WITH THE OWNER AS TFD HAD ALREADY EXITED THE SITE,OWNER WALKED ME THRU THE KITCHEN AREA WHERE THE FIRE HAD OCCURED. MY INSPECTION FOUND THE HOOD ABOVE THE STOVE HAD ARCED AND POSSIBLY STARTED FIRE. THE CABINETS TO THE RIGHT SIDE OF THE RANGE HOOD HAD ALSO BURNED AND TFD REMOVED THE BACKS OF THE CABINET TO GET INSIDE THE WALL. THERE WAS AND OLD JUNCTION BOX AND OTHER WIRING FROM A REMODEL THAT WAS NEVER REMOVED AND POWER HAD BEEN TURNED OFF BY TFD. THERE WERE ALSO HOLES IN THE CEILING DRYWALL AND IN THE WALL FROM TFD CHASING THE FIRE TO DETERMINE IF THE FIRE SPREADBUT THERE WAS NO FIRE IN THE CELING OR ENTRY WALL TO THE KITCHEN, FIRE WAS LIMITED TO THE HOOD AND CABINET. OWNERS DAUGTER WAS ON SITE AND THE MOTHER AND FATHER INFORMED ME THEY WOULD BE STAYING WITH HER DAUGHTER WHO CONFIRMED THE ARRANGEMENTS. THE OWNER HELPED ME CHECK THE MAIN SERVICE PANEL, I CHECKED THE MAIN SERVICE PANEL AND TURNED THE BREAKER ON TO THE REFRIGERATOR/ FREEZER ONLY, OWNER STATED HE WOULD WAIT UNTIL ELECTRICIAN SHOWED. I ASKED WHEN THE ELECTRICIAN WAS ON SITE THAT THEY HAVE HIM REMOVE THE UNNECESSARY WIRING AND JUNCTION BOX. NOV WAS ISSUED TO MAKE CABINET, DRYWALL, AND FIXTURE REPAIRS (HOOD). A PERMIT WILL NOT BE REQUIRED AS NONE OF THE ITEMS REQUIRE A PERMIT. I INFORMED THE OWNER THAT ONCE INSURANCE WAS OUT THEY COULD START THE CLEAN UP OF THE KITCHEN, AND ASKED THEY CONTACT ME ONCE THE ELCTRICIAN HAS CHECKED THE ELECTRICAL SYSTEM AND REMOVED THE WIRING. OWNER INFORMED ME THAT THE INSURANCE COMPANY HAS BEEN CONTACTED, CANYON CABINETRY AND CONSTRUCTION WHO DID THE PREVIOUS REMODEL WAS ALSO CONTACTED. C/E HAS NO FURTHER ISSUES.
11/09/2022 COT - ENFC - Code Enforcement - Follow Up Passed REVISITED SITE, FOUND KITCHEN AREA HAD BEEN CLEANED, CABINETS HAD BEEN REMOVED AND ELECTRICAL WIRING AND BOX REMOVED FROM THE WALL, AND MINOR PATCHES COMPLETED TO THE CEILING AND SOUTH KITCHEN WALL. DRYWALL WAS CUT BUT NOT INSTALLED FOR BEHIND THE CABINETS. CABINETS HAVE ALSO BEEN ORDERED. I INFORMED THE OWNER THAT MY MAIN CONCERN WAS THE ELCTRICAL BEING REMOVED AND THAT I DID NOT NEED TO SEE THE CABINETS INSTALLED OR THE KITCHEN PAINETED AS THEY ARE NON PERMITTED ISSUES. C/E HAS NO FURTHER ISSUES AT THIS TIME. COMPLIANCE / CLOSE CASE.