Closed - Resolved

Type:

RMIN : Rodent infestation, no electricity in laundry room, no air going to one of the bedrooms, and leak from cooler
Address:

Entered Date:

08/06/2025

Applicant:

N/A

Description:

Completed Inspections

Case Status: Closed - Resolved
Case Number: CE-VIO0825-03330
Case Description: RMIN : Rodent infestation, no electricity in laundry room, no air going to one of the bedrooms, and leak from cooler
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/13/2025 COT - ENFC - Code Enforcement - Initial Completed On 8/13/2025, I inspected 721 E Bilby Road with Inspector Robert Gonzalez. The following violations were noted: Electrical – Kitchen: Outlet near sink lacks GFCI protection, creating a safety hazard. Plumbing/Water Damage – Evaporative Cooler: When off, leaks significant water, causing kitchen ceiling damage and exterior wood rot. Heating/Cooling – Bedroom #2: No heating or cooling system installed. Window – Bedroom #2: Broken glass and defective exterior pane. Cabinetry – Kitchen: Drawers lack tracks/dovetails; holes in wooden frames. Interior Wall Coverings: Defective plaster under bathroom/kitchen cabinets; cardboard divider under kitchen sink. Fence – Rear Yard: Missing slats; gate unstable and cannot be fastened. Electrical Panel Access: Obstructed by wooden fence. Fuse Box Safety: Missing cover, exposing electrified wiring near cooler leak. Rodent Infestation: Droppings in kitchen and living room. Heating – Entire Dwelling: No permanent heating system. Closet Door – Bedroom #1: Unfastened, untracked, freestanding. Water Damage – Kitchen Ceiling: Visible damage with crack. Bathroom Tile: Broken tile. Plumbing – Kitchen Sink: PVC pipes secured with tape. Appliance – Oven: Missing oven door handle. These conditions violate applicable housing, building, electrical, and health codes, posing significant safety, habitability, and sanitation concerns.
12/11/2025 COT - ENFC - Code Enforcement - Follow Up Completed The tenent is no longer in the unit. Upon making many of the repairs, the management company was surprised to hear that a permanent heating system was required for rental, not just space heaters. Upon hearing this, they indicated they would no longer rent the unit in question.

Documents

File Name Document Type  
TC_00480.JPEG DOCUMENTS VIEW
TC_00481.JPEG DOCUMENTS VIEW
TC_00482.JPEG DOCUMENTS VIEW
TC_00483.JPEG DOCUMENTS VIEW
TC_00484.JPEG DOCUMENTS VIEW
TC_00485.JPEG DOCUMENTS VIEW
TC_00486.JPEG DOCUMENTS VIEW
TC_00487.JPEG DOCUMENTS VIEW
TC_00490 (1).MOV DOCUMENTS VIEW
TC_00491.JPEG DOCUMENTS VIEW
TC_00492.JPEG DOCUMENTS VIEW
TC_00493.JPEG DOCUMENTS VIEW
TC_00494.JPEG DOCUMENTS VIEW
TC_00495.JPEG DOCUMENTS VIEW
TC_00496.JPEG DOCUMENTS VIEW
TC_00497.JPEG DOCUMENTS VIEW
TC_00498.JPEG DOCUMENTS VIEW
TC_00501.JPEG DOCUMENTS VIEW
TC_00502.JPEG DOCUMENTS VIEW
TC_00503.JPEG DOCUMENTS VIEW
TC_00504.JPEG DOCUMENTS VIEW
TC_00505.JPEG DOCUMENTS VIEW
TC_00506.JPEG DOCUMENTS VIEW
TC_00507.JPEG DOCUMENTS VIEW