Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

Active

Type:

EMER - TPD Emergency Callout for Uninhabitable and Substandard Living Conditions
Address:

Entered Date:

01/07/2026

Applicant:

N/A

Description:

Completed Inspections

Case Status: Active
Case Number: CE-VIO0126-00079
Case Description: EMER - TPD Emergency Callout for Uninhabitable and Substandard Living Conditions
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/07/2026 COT - ENFC - Code Enforcement - Initial In Violation 133 AM - Called out to site by TPD. Owner of property left upon my arrival and did not want to wait to speak to me. The front door is inoperable and will not open, is boarded shut from the inside. From the front window, can see more than half of the ceiling in the living room area has collapsed. The front porch appears to have large areas of roof decking replaced. Wood on beams appears to be missing weather protection. There is unsafe electrical to include exposed wiring in the structure, use of extension cords throughout, the dead front from the main panel is removed and there are exposed wires sticking out of the panel. Extension cords ran throughout the backyard to power tents for apparent homeless encampments in the rear yard. Per TPD there is feces inside the home. Egress is blocked, hallways and pathways are blocked by items including debris. The bathroom sink is being held up by a bungee cord attached to the roof structural members. There is excessive trash and debris throughout the property, posted a 30 day notice for this item. The home is condemned and may not be occupied. Electric service is to be cut at the pole, permit is required for reconnect. -VM
04/15/2026 COT - ENFC - Code Enforcement - Follow Up In Violation Called owner, no answer, left voicemail. Will wait 1 week for a return call before proceeding.

Scheduled Inspections

SCase Number - CE-VIO0126-00079
Case Status: Active
Case Description:
Scheduled Date Description Inspector Status
04/23/2026 COT - ENFC - Code Enforcement - Follow Up Scheduled

Documents

File Name Document Type  
4833 23RD F_U (1).JPG DOCUMENTS VIEW
4833 23RD F_U (2).JPG DOCUMENTS VIEW
4833 23RD F_U (3).JPG DOCUMENTS VIEW
4833 23RD F_U (4).JPG DOCUMENTS VIEW
4833 23RD F_U (5).JPG DOCUMENTS VIEW
CE-VIO0126-00079 01 EAOV.PDF DOCUMENTS VIEW
CE-VIO0126-00079 02 NOV.PDF DOCUMENTS VIEW
IMAGES 2026-01-07 CE-VIO0126-00079.PDF DOCUMENTS VIEW