| H000012617 | CLOSED | 12/11/2020 | N/A | Historical Information |
Permits
Address: 1356 W CLAUSEN CI
Date - 11/23/2026 7:19 p.m.
Total Number Of Permits - (7)
| Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TC-RES-0524-03268 | Inspections | 05/30/2024 | 05/19/2025 | Residential Building - One or Two Family | Renovate SFR +The trusses in between the 1st and 2nd floor have a 1/12 pitch so all the floors upstairs are slanted. +The beams that run between columns on rear of home are the wrong size and starting to sag. +There are 2 walk-deck areas that currently have rolled roofing instead of coating and the railings are too short +The foam roof leaks on almost every slope +None of the windows have flashing and all leak +The rise & run of the stairs is wrong and the treads are too short. Also the entire staircase is not attached to the foundation, it's nailed into an adjacent wall and top of stair into 2nd story +Areas of drywall had to be removed for framing inspection | |
| DS14-06 | Approved | 03/25/2014 | N/A | Zoning Verification Letter | PDMR/TSMR - PDMR/TSMR PDMSR UDC 7.4.6.D - reduce width of PAAL TSMR 7-01.4.0.F - locate sidewalk between garage and PAAL | |
| DP13-0250 | CLOSED | 12/16/2013 | 08/08/2021 | DEVPKG | SITE & GRADING | |
| DS14-05 | VOID | 03/25/2014 | N/A | DEVSTDS | TSMR/PDMR | |
| T19CM01031 | C OF O | 02/11/2019 | 06/08/2020 | COMBO | NEW SFR | |
| T19RW06768 | FINAL | 11/04/2019 | 12/04/2019 | ROW | WILL CUT STREET OR DRIVE IN ORDER TO INSTALL A HCS (T19CM01031) This project is located in an ARCHAELOGICAL SENSITIVE ZONE. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Please contact Allison Diehl at allison.diehl@tucsonaz.gov with any questions. | |
| T19RW07715 | FINAL | 12/24/2019 | 01/26/2020 | ROW | (2) 5X5 BELLHOLES IN DIRT FRONT - TO INSTALL NEW GAS LINE This project is located in an ARCHAELOGICAL SENSITIVE ZONE. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Please contact Allison Diehl at allison.diehl@tucsonaz.gov with any questions. |