Activity Search: TC-RES-0926-05338
Activity
Parcel Attributes
| Parcel | 133152140 |
|---|---|
| Jurisdiction | Tucson, Pima County |
| City of Tucson Zoning | R-2 |
| Tucson Ward | Ward 2 |
| Tucson Registered Neighborhood | Udall Park |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Address | |
| Parcel Attributes Issue? | |
Permits
Date - 11/27/2026 8:05 p.m.
Number Of Permits - (1)
| Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TC-RES-0926-05338 | Inspections | 09/24/2026 | 10/27/2027 | Residential Building - One or Two Family | Upgrade main electrical service due to age and condition. Remove existing General Electric split buss load center. Remove existing meter base. -Install (1) 200amp-220volt Milbank meter base. Install (1) 200amp-220volt Eaton Cutler Hammer 30 space main breaker load center. Install new TEP feeder cables. -Install all existing branch circuitry into new load center. Properly terminate all ground and nuetral wiring. Install new breakers for all existing circuitry to include (1) 90amp-220volt, (2) 50amp-220volt, (1) 30amp-220volt, (6) 20amp-110volt, (1) and (4) 15amp-110volt Eaton Cutler Hammer circuit breakers. -Install (1) grounding system to include (2) ground rods bonded to gas and water. -Obtain permits, submit applications, and coordinate inspections with TEP and City of Tucson. -Install (1) Eaton Cutler Hammer ULTRA2 home surge protector on main electrical service. Install (1) Eaton Cutler Hammer 50amp-220volt circuit breaker to operate new device. |