Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Activity

 

Parcel Attributes

Parcel123070050
JurisdictionTucson, Pima County
City of Tucson ZoningR-1
Tucson WardWard 6
Tucson Registered NeighborhoodBlenman-Elm
National Register Historic DistrictBlenman-Elm Historic District
Structure on National Register of Historic Places

Contributor

Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Address
Parcel Attributes Issue?

Permits

Date - 11/16/2026 1:17 p.m.
Number Of Permits - (1)
Permit Status Apply Date Expired Date Unit Type Description
TC-RES-0126-00222 Complete 01/16/2026 07/12/2027 Residential Building - One or Two Family This project consists of a non-structural interior remodel of an existing single-family residential dwelling located within the City of Tucson, Arizona. All existing structural elements shall remain intact. No changes to the building footprint, structural system, roof structure, foundations, or load-bearing components are proposed. The scope of work includes, but is not limited to, the following: Interior modification and refinishing of non-load-bearing partition walls Replacement and/or refinishing of ceilings, including gypsum board, soffits, and finishes Installation of new flooring materials. Updated interior finishes, including wall finishes, trim, cabinetry, and millwork Replacement and installation of fixtures, including lighting fixtures, plumbing fixtures, and related hardware Minor electrical and plumbing adjustments necessary to accommodate new fixtures and finishes; no utility service upgrades are proposed Existing residential use, occupancy classification, and means of egress shall remain unchanged REV1: 1. Restroom Layout The restroom layouts have been revised to reflect the existing field configuration as constructed. The contractor maintained the original existing restroom arrangement rather than the layout shown on the previously approved permit drawings. The revised plans now accurately represent the existing configuration. 2. Kitchen Layout The kitchen layout remains consistent with the originally approved permit plans. No changes to the kitchen cabinet or fixture layout have been made in this revision. Electrical devices, including switches and receptacles, have been revised to reflect the actual field installation. 3. Electrical Plan Revisions The electrical plans have been updated to match the existing installation conditions within the residence, including lighting locations, switches, and receptacle locations where modified during construction

Documents

File Name Document Type  
LOFC_LETTEROFCOMPLETION (SSRS).PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-DRACHMAN 2ND REVISION_V2.PDF DOCUMENTS VIEW
REVISION LETTER_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-DRACHMAN PLANS_V1.PDF DOCUMENTS VIEW