Permit Status Apply Date Expired Date Unit Type Description
TC-RES-0125-00470 Expired 01/24/2025 N/A Residential Building - One or Two Family Customer had an increase in her gas bill... Sw Gas came out and shut the gas off to the home...SW gas tested through the test port... When the plumber arrived at the home, a few of the connections at the gas meter seemed to be loose. We redid a few of the connections so that we could perform a gas test...After connections were redone, we performed a gas test letting the gauge sit for 4 hours to ensure there were no more leaks... gauge only lost 1.5 PSI over 4 hours...Everything passed the gas test...customer was told by SW gas that the regulator on the utility side of the meter may possibly be bad and they would also test it. Due to gas pressure test passing, gas can be turned on to the home.