Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Activity

 

Parcel Attributes

Parcel10408093B
JurisdictionTucson, Pima County
Water Course

Wash

City of Tucson ZoningC-3, C-2
Tucson WardWard 3
Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Address
Parcel Attributes Issue?

Permits

Date - 08/18/2026 7:25 p.m.
Number Of Permits - (1)
Permit Status Apply Date Expired Date Unit Type Description
TC-COM-1124-02131 Complete 11/06/2024 05/26/2025 Commercial Building On arrival checked gas line on side of garage and began to chase pipe. Located gas line pipe and set air gauge to pressure test gas line for any leaks. Set pressure at 15psi and began to apply soap to pipe and fittings in an attempt to find leaks No leaks were present at this time. Also air gauge did not go down in pressure. Will get a hold of maintenance to show results. Maintenance will need get of hold of southwest gas and present them with what we have done Tested for 2 plus hours to monitor the gauge as it continued to hold at 15psi Advised By SW Gas that a "City" inspected pressure test will be needed to turn gas back on.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-WATSON GAS TEMPLATE_V1.PDF DOCUMENTS VIEW